ABB i-bus

®

KNX Inputs

Type DetailOrder code PG MW ** Type DetailOrder code PG MW ** * *

Binary Inputs, 230 V AC/DC, MDRC Analogue Input, 4-fold, MDRC

For the detection of 230 V AC/DC signals. The state of the inputs is displayed via LEDs. The binary inputs enable the detection of 4 or 8 signals. Each channel has a push button for manual operation. The devices are supplied by the ABB i-bus The analogue input AE/S 4.2 is used to detect and process 4 independent analogue input signals accord- ing to DIN IEC 60381 (0 – 1 V, 0 – 5 V, 0 – 10 V, 0 – 20 mA, 4 – 20 mA, 0 – 1000 Ohm, PT 100 in 2-wire technology and floating contacts). The integrated 115/230 V power supply generates the 24 V DC voltage for external sensors.
2CDC 071 594 F0004 ® , no additional power supply is neccessary. Bus connection via bus connection terminals. AE/S 4.2
2CDC 071 174 F0004 2CDG 110 030 R0011 26 4 BE/S 4.230.1 4-fold2CDG 110 051 R0011 26 2 BE/S 8.230.1 8-fold2CDG 110 054 R0011 26 4

Analogue Input, 4-fold, LF

to be discontinued

Binary Inputs, 24 V AC/DC, MDRC

6157 EB-500 The 4-fold analogue input is used to detect and process analogue variables. The four measure ment channels can be configured for various current or voltage signals e.g. 0…20 mA, 0…1 V, 0…10 V, etc. The device requires a 230 V AC power supply. A 24 V DC auxiliary voltage for the supply of external sensors is generated by the device. 6157-0-0028 26 – For the detection of 24 V AC/DC signals. The state of the inputs is displayed via LEDs. The binary inputs enable the detection of 4 or 8 signals. Each channel has a push button for manual operation. The devices are supplied by the ABB i-bus
SK 0075 B95 2CDC 071 009 F0005 ® , no addi-tional power supply is neccessary. Bus connection via bus connection terminals. BE/S 4.24.1 4-fold2CDG 110 052 R0011 26 2 BE/S 8.24.1 8-fold2CDG 110 055 R0011 26 4

Weather Station, 4-fold, MDRC Binary Inputs, Contact Scanning, MDRC

The weather station WS/S 4.1 is used to detect and process 4 independent input signals from weather instrumen tation according to DIN IEC 60381 (0 – 1 V, 0 – 5 V, 0 – 10 V, 0 – 20 mA, 4 – 20 mA, 0 – 1000 Ohm, For the interrogation of potential free contacts using an internally generated scanning voltage. The state of the inputs is displayed via LEDs. The binary inputs enable the detection of 4 or 8 contact circuits. Each channel has a push button for manual operation. The devices are supplied by the ABB i-bus PT 100). The integrated 115/230 V power supply generates WS/S 4.1
2CDC 071 175 F0004 the 24 V DC voltage for external sensors. All common weather sensors for wind speed, wind direc- tion, rain, amount of rain, brightness, luminaire intensity, twilight, air pressure, humidity or temperature providing standard DIN signals can be connected to the device. 2CDG 110 032 R0011 26 4
2CDC 071 593 F0004 ® , no additional power supply is neccessary. Bus connection via bus connection terminals. BE/S 4.20.1 4-fold2CDG 110 053 R0011 26 2 BE/S 8.20.1 8-fold2CDG 110 056 R0011 26 4

Binary Inputs, 4-fold, LF

WZ/S 1.1

Weather Unit, MDRC

2CDG 110 034 R0011 26 4 to be discontinued The weather unit WZ/S 1.1 is used to detect and process For the detection of 230 V AC or 24 V AC/DC signals. The device 6158 EB-500 can also be used for the interrogation of floating contacts using the integrated 24 V supply when the device is connected to 230 V AC. weather data from the weather sensor. The weather sensor supplies the unit with data, i.e., of light and brightness levels in 3 directions, rain, temperature, information on day/night, wind speed, date and time. The weather unit WZ/S 1.1 can only be used with the weather sensor WES/A 1.1. The device can be oper- ated with a suppy voltage of 115 to 230 V, 50/60 Hz. 6156 EB-500 230 V AC6156-0-0020 26 – 6158 EB-500 24 V AC/DC6158-0-0026 26 –
2CDC 071 201 F0004 SK 0078 B95 US/U 2.2 2-foldGH Q631 0074 R0111 26 – WES/A 1.1 2CDG 120 003 R0011 20 – US/U 4.2

Universal Interfaces, FM

4-foldGH Q631 0070 R0111 26 –

Weather Sensor

The universal interface has 2 or 4 channels respectively which can be parameterised as inputs or outputs. Con- ventional push-buttons, auxiliary contacts, LEDs and the electronic relay ER/U 1.1 can be used together with the device to fulfill a wide variety of applications. The connecting cables can be extended up to 10 m. The contact scanning voltage and the supply voltage for the LEDs are made available by the device. The weather sensor WES/A 1.1 records twilight, brightness in 3 directions, rain (permanently heated detection surfaces at temperatures < 10 °C or when raining), temperature, information on day/night, wind speed, date and time (DCF radio receiver). An addi- tional heating transformer is not needed. The weather sensor WES/A 1.1 can only be used with the weather unit WZ/S 1.1.
2CDC 071 057 F0004 SK 0093 B02 MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting,

11

LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm
ArchiExpo's Virtual Library: PDF Catalogues | Documentation | Brochures | Manuals | Directory | Specifications | Characteristics
Search Go
page 1 p.1
page 2 p.2
page 3 p.3
page 4 p.4
page 5 p.5
page 6 p.6
page 7 p.7
page 8 p.8
page 9 p.9
page 10 p.10
page 11 p.11
page 12 p.12
page 13 p.13
page 14 p.14
page 15 p.15
page 16 p.16
page 17 p.17
page 18 p.18
page 19 p.19
page 20 p.20
page 21 p.21
page 22 p.22
page 23 p.23
page 24 p.24
page 25 p.25
page 26 p.26
page 27 p.27
page 28 p.28
page 29 p.29
page 30 p.30
page 31 p.31
page 32 p.32
page 33 p.33
page 34 p.34
page 35 p.35
page 36 p.36
page 37 p.37
page 38 p.38
page 39 p.39
page 40 p.40
page 41 p.41
page 42 p.42
page 43 p.43
page 44 p.44
page 45 p.45
page 46 p.46
page 47 p.47
page 48 p.48
page 49 p.49
page 50 p.50
Pages:
1 - 50
51 - 70
pdf-page pdf ae En 2009-11-48-24