KNX Range 2011_12 - 72 Pages
ABB i-bus® KNX Security and Surveillance Type Detail Order code PG MW Type Detail Order code PG MW 3 3 Optical Smoke Detector Optical smoke detector in threshold alarm technology that detects smoke according to the scattered-light principle The detectors feature an alarm indicator on the detector head that is visible from all angles, and which can be be triggered with a permanent magnet for test purposes. A detector base is provided for mounting and cable connection purposes into which the detector is simply screwed in via the bayonet connection. Each detector is equipped with an alarm LED, which displays the stored alarm in the event of an a alarm Detector/base diameter: 110 mm. VdS approved. 2CDG 430 079 R0011 52 - Siren in Enclosure An aluminium protective housing with additional protective enamel coating. Protected against sabotage by a case tamper contact. The alarm inputs are wired onto a terminal strip. With fixing screw (M4) for potential equalization on the base. Dimensions: H x W x D = 200 x 205 x 88 mm; Color: RAL 9002 Environmental class III to VdS GH Q305 0017 R0001 50 SSF/G FC650/O Combination Signalling Device Siren in an aluminium protective housing with additional protective enamel coating and strobe light mounted on top. Protected against sabotage by a case tamper contact. The alarm inputs are wired onto a terminal strip. Dimensions: H x W x D = 258 x 205 x 88 mm; Color RAL 9002. VdS No. G 101147. VdS class C. GH Q305 0018 R0001 50 - Busch Smoke Alarm® ProfessionalLine For early detection of smouldering fires and open fires with smoke development indoors according to the photo-optical measurement principle (Tyndall). With installed Lithium battery. Battery life min. 10 years. With test button and muting. Can be networked with up to 12 detectors using the radio module. Can be networked via 2-wire twisted pair cable with up to 12 detectors. Acoustic alarm: installed horn (85 dBA). Cyclic functional test. Including attachment material- VdS certified. Conform to EN 14604. 3 3 Heat Detector Static Heat Detector in threshold alarm technology, - trigger temperature 78°C. The detectors feature an alarm indicator on the detector head that is visible from all angles, and which can be be triggered with a permanent magnet for test purposes. A detector base is provided for mounting and cable connection purposes into which the detector is simply screwed-in via the bayonet connection. Each detector is equipped with an alarm LED, which displays the stored alarm in the event of an a alarm. Detector/base diameter: 110 mm. VdS approved. 2CDG 430 081 R0011 52 - SSF/GB FC650/TMAX 5 3 Detector Base, 12 V Enables system-independent connection of the FC650 series fire detector to systems or devices that are not specifically designed for this detector technology. Examples include Intrusion Alarm Panels, KNX Security Terminals, elevator controls or other signal processing equipment. The detector base must be supplied by either a 12 V or a 24 V DV voltage supply. A floating 30 V DC/1 A changeover contacting is provided for transferring an alarm. 2CDG 430 051 R0011 52 - Testing Aerosol For optical smoke detector testing, 250 ml. 6826-84 studio white 6800-0-2512 14 Busch Heat Alarm ProfessionalLine Signal triggered at over 57 °C. With installed Lithium battery. Battery life min. 10 years. With test button and muting. Can be networked via 2-wire twisted pair cable with up to 12 detectors. Can be networked with up to 12 detectors using the radio module. Acoustic alarm: installed horn (85 dBA). Cyclic functional test. Including attachment material - VdS certified. Conform to EN 14604. FC600/BREL 6827-84 studio white 6800-0-2513 14 GH V902 0012 V0021 52 Busch Smoke Alarm® Radio Module For wireless networking of multiple Busch smoke alarms® / heat alarms. With installed Lithium battery. Battery life min. 10 years. Radio frequency: 868 MHz. Range: max. 100 m outdoors, max. 30 m indoors. FPA03 RL Reed Relay, 12 V For connection, e.g. to transistor outputs of Intrusion Alarm Panels. Coil voltage 8.5...14 V DC. Current con-sumption 5 mA at 12 V DC. Contact loading 24 V/100 mA. 6800-0-2514 14 - Busch Smoke Alarm® Relay For connecting external systems, e.g. KNX. Relay contact, floating changeover contact 230 V~ max. 5 A. Cable connection: up to 2 x 2 x 1.5 mm2. With installed radio module. Rated voltage: 230 V~ 6828 GH V927 0013 V0100 52 -Electronic Solid-State Siren Electronic solid-state siren with intermittent tone for alarm purposes in indoor installations. External dimensions: 0 x H = 90 x 37 mm. X 6829-84 studio white 6800-0-2515 14 Busch Smoke Alarm® Remote Control For service purposes. With muting, test and search function. SSS GH V927 0001 V0001 50 6824-84 studio white 6800-0-2516 14 MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting, LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm 49
-
P. 1
-
P. 46
ABB i-bus® KNX Intrusion Alarm System L240 Overview Intrusion Alarm System L240 6 detector circuits, 1 PA, 1 tamper, 1 lock, 1 external set ///////... -
P. 47
ABB i-bus® KNX Security and Surveillance Type Detail Order code PG MW Type Detail Order code PG MW V Fault Monitoring Unit, MDRC It is used to detect... -
P. 48
ABB i-bus® KNX Security and Surveillance Type Detail Order code PG MW Type Detail Order code PG MW g BUS-Infra-Red Motion Detector ° For... -
P. 49
ABB i-bus® KNX Security and Surveillance Type Detail Order code PG MW Type Detail Order code PG MW 2 Security Terminal, 4-fold, MDRC They are used... -
P. 50
ABB i-bus® KNX Security and Surveillance Type Detail Order code PG MW Type Detail Order code PG MW Window Lock Monitoring Contact Lock monitoring... -
P. 51
-
P. 52
ABB i-bus® KNX Frames Type Dtail Order code PG MW Type Detail Order code PG MW Frames, future® linear For vertical and horizontal installation.... -
P. 53
ABB i-bus® KNX Frames Type Dtail Order code PG MW Type Detail Order code PG MW Frames, axcent For vertical and horizontal... -
P. 54
Unique diversity of the range 01 02 _ , _ Il 03 _ _ i V l'C 04 Inner qualities and external beauty. Busch-Jaeger switch ranges turn into a reality what... -
P. 55
Unique diversity of the range 06 carat® alpha 02 pure stainless steel 07 Reflex SI / SI linear 03 solo® 8 Busch-Duro 2000® SI 04 Busch-axcent®... -
P. 56
ABB i-bus® KNX Slection Table According to Order Code Order code Description Type EAN PG Page 1754-0-4104 Frame, 1-fold chrome, matt 1721-80 40 11395... -
P. 57
-
P. 58
-
P. 59
-
P. 60
-
P. 70