Stand
Group: ABB

KNX Range 2011_12 - 72 Pages

ABB i-bus® KNX Control, Logic and Time Type Detail Order code PG MW Type Detail Order code PG MW i 8 Logic Module, MDRC Used to solve a varied range of project-specific control 3 tasks and can implement 3 functions simultaneously. ^ g The following functions are available for sélection: logic gte, filter, time delay, multiplier, min/max value detector, temperature comparator, toggle values, threshold dtection, format converter, sc⩨nes, incrment/ decrement values, staircase lighting. LM/S 1.1 GH Q631 0080 R0111 26 2 Antenna for Radio Time Switch, SM Antenna for connection to the DCF-Time switch FW/S 4.5. The time signal from the DCF 77 transmitter can be received within a radius of approx. 1000 km around Frankfurt. FA/A 2.1 GH Q605 0031 R0021 20 Application Unit, Logic, MDRC Allows the compilation of complex logical functions by simply combining different logic elements and gates using a graphical user interface as an ETS plug-in and does not require additional software. 50 logical elements, 50 gates, 30 timer modules and 10 comparators are available. Programming Set The programming set contains a CD ROM with the Ob-elisk software for the creation of switching programs for the timers SW/S 4.5 and FW/S 4.5, a memory card PK/E for transferring switching programs and for data security, a programming adapter for the memory card for connection to a PC (RS 232) and a manual. ABL/S 2.1 2CDG 110 073 R0011 26 2 PS/E 1.1 PK/E 1.1 Programming Set Memory Card GH Q600 1942 R0001 20 GH Q600 1943 R0001 20 Application Unit, Time, MDRC It provides a yearly time clock program with 15 daily routines (800 switching events), a weekly schedule and § allowance for 100 sp魩cial days. Additionally, the unit can c c control up to 300 participants in 30 macro groups, that can be triggered using a single command. In this way, each time controlled switching event can cause a series of actions. The switching times can be modified with the free PZM 2.0 software without using ETS. ABZ/S 2.1 2CDG 110 072 R0011 26 2 Time Switch, 2-channel, MDRC Provides timed switching in a weekly program of electri-g cal loads. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. 8 24 memory locations with configurable block formation w of weekdays. SW/S 2.5 GH Q605 0062 R0001 20 2 Time Switch, 4-channel, MDRC Provides timed switching in a daily, weekly and yearly program of electrical loads. The time and date are sent to synchronise other bus devices on the bus. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. The programming of the switching times is carried out on the clock or via the PC in conjunction with the memory card PK/E and the programming set PS/E. SW/S 4.5 GH Q605 0061 R0001 20 6 Radio Time Switch, 4-channel, MDRC With daily, weekly and yearly program, receives the time signal from the DCF 77 transmitter via antenna FA/A. The time and date are sent to synchronise other bus devices on the bus. The radio timer provides timed switching of electrical loads. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. The programming of the switching times is carried out on the clock or via the PC in conjunction with the memory card PK/E and the programming set PS/E. FW/S 4.5 GH Q605 0060 R0001 20 6 30 MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting, LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm

KNX Range 2011_12
  1. P. 1

  2. P. 27

    Rgulation of Room Temprature und Air Quality Influencing Variables on Room Climate Influencing Variables on Room Temp驩rature Influencing Variables...
  3. P. 28

    ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW Blower / Fan Coil Actuator, MDRC Developed especially...
  4. P. 29

    ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW il Electromotor Valve Drive The drive is a proportional...
  5. P. 30

    ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW Room Thermostat with Display and 2/4-fold Switch Sensor,...
  6. P. 31

    ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW 5 Cover Plate for Room Thermostat, Commercial For room...
  7. P. 32

  8. P. 33

    ABB i-bus® KNX Visualisation, Display and Signalling Type Detail Order code PG MW Type Detail Order code PG MW 5 3 Universal I/O Concentrator, 32-fold,...
  9. P. 34

    ABB i-bus® KNX Visualisation, Display and Signalling Type Detail Order code PG MW Type Detail Order code PG MW Control and Display Tableau, LCD For...
  10. P. 35

    Multifunction control lments with LED colour code concept. And the utmost in comfort. Light 驗 Heating The new multifunction control elements with...
  11. P. 36

    04 05 06 07 ..M d i Function Comfort | Stand-by | Night mode | Frost protection | Specified temperature | Time | Date | Heating | Cooling | Fan Coil operation...
  12. P. 37

    ABB i-bus® KNX Opration Type Dtail Order code PG MW Type Detail Order code PG MW Universal Interface, FM The universal interface has 2, 4 or 12 channels...
  13. P. 38

  14. P. 39

  15. P. 40

  16. P. 50

  17. P. 60

  18. P. 70

Text version

All ABB STOTZ-KONTAKT catalogues and technical brochures

Archived catalogues

  1. KNX Flash

    20 Pages

    En