KNX Range 2011_12 - 72 Pages
ABB i-bus® KNX Control, Logic and Time Type Detail Order code PG MW Type Detail Order code PG MW i 8 Logic Module, MDRC Used to solve a varied range of project-specific control 3 tasks and can implement 3 functions simultaneously. ^ g The following functions are available for sélection: logic gte, filter, time delay, multiplier, min/max value detector, temperature comparator, toggle values, threshold dtection, format converter, sc⩨nes, incrment/ decrement values, staircase lighting. LM/S 1.1 GH Q631 0080 R0111 26 2 Antenna for Radio Time Switch, SM Antenna for connection to the DCF-Time switch FW/S 4.5. The time signal from the DCF 77 transmitter can be received within a radius of approx. 1000 km around Frankfurt. FA/A 2.1 GH Q605 0031 R0021 20 Application Unit, Logic, MDRC Allows the compilation of complex logical functions by simply combining different logic elements and gates using a graphical user interface as an ETS plug-in and does not require additional software. 50 logical elements, 50 gates, 30 timer modules and 10 comparators are available. Programming Set The programming set contains a CD ROM with the Ob-elisk software for the creation of switching programs for the timers SW/S 4.5 and FW/S 4.5, a memory card PK/E for transferring switching programs and for data security, a programming adapter for the memory card for connection to a PC (RS 232) and a manual. ABL/S 2.1 2CDG 110 073 R0011 26 2 PS/E 1.1 PK/E 1.1 Programming Set Memory Card GH Q600 1942 R0001 20 GH Q600 1943 R0001 20 Application Unit, Time, MDRC It provides a yearly time clock program with 15 daily routines (800 switching events), a weekly schedule and § allowance for 100 sp魩cial days. Additionally, the unit can c c control up to 300 participants in 30 macro groups, that can be triggered using a single command. In this way, each time controlled switching event can cause a series of actions. The switching times can be modified with the free PZM 2.0 software without using ETS. ABZ/S 2.1 2CDG 110 072 R0011 26 2 Time Switch, 2-channel, MDRC Provides timed switching in a weekly program of electri-g cal loads. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. 8 24 memory locations with configurable block formation w of weekdays. SW/S 2.5 GH Q605 0062 R0001 20 2 Time Switch, 4-channel, MDRC Provides timed switching in a daily, weekly and yearly program of electrical loads. The time and date are sent to synchronise other bus devices on the bus. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. The programming of the switching times is carried out on the clock or via the PC in conjunction with the memory card PK/E and the programming set PS/E. SW/S 4.5 GH Q605 0061 R0001 20 6 Radio Time Switch, 4-channel, MDRC With daily, weekly and yearly program, receives the time signal from the DCF 77 transmitter via antenna FA/A. The time and date are sent to synchronise other bus devices on the bus. The radio timer provides timed switching of electrical loads. Each channel can switch a load group ON or OFF or send a brightness value to dimming actuators. The programming of the switching times is carried out on the clock or via the PC in conjunction with the memory card PK/E and the programming set PS/E. FW/S 4.5 GH Q605 0060 R0001 20 6 30 MDRC = Modular DIN-rail Component, SM = Surface Mounting, FM = Flush Mounting, LF = Light Fitting, *PG = Price Group, **MW = Module Width 18 mm
-
P. 1
-
P. 27
Rgulation of Room Temprature und Air Quality Influencing Variables on Room Climate Influencing Variables on Room Temp驩rature Influencing Variables... -
P. 28
ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW Blower / Fan Coil Actuator, MDRC Developed especially... -
P. 29
ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW il Electromotor Valve Drive The drive is a proportional... -
P. 30
ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW Room Thermostat with Display and 2/4-fold Switch Sensor,... -
P. 31
ABB i-bus® KNX Heating and Cooling Type Detail Order code PG MW Type Detail Order code PG MW 5 Cover Plate for Room Thermostat, Commercial For room... -
P. 32
-
P. 33
ABB i-bus® KNX Visualisation, Display and Signalling Type Detail Order code PG MW Type Detail Order code PG MW 5 3 Universal I/O Concentrator, 32-fold,... -
P. 34
ABB i-bus® KNX Visualisation, Display and Signalling Type Detail Order code PG MW Type Detail Order code PG MW Control and Display Tableau, LCD For... -
P. 35
Multifunction control lments with LED colour code concept. And the utmost in comfort. Light 驗 Heating The new multifunction control elements with... -
P. 36
04 05 06 07 ..M d i Function Comfort | Stand-by | Night mode | Frost protection | Specified temperature | Time | Date | Heating | Cooling | Fan Coil operation... -
P. 37
ABB i-bus® KNX Opration Type Dtail Order code PG MW Type Detail Order code PG MW Universal Interface, FM The universal interface has 2, 4 or 12 channels... -
P. 38
-
P. 39
-
P. 40
-
P. 50
-
P. 60
-
P. 70