KNX Range 2011_12 - 72 Pages
ABB i-bus® KNX Inputs Binary Inputs Slection Table BE/S 4.20.2.1 BE/S 4.230.2.1 BE/S 8.20.2.1 BE/S 8.230.2.1 US/U 2.2 US/U 4.2 US/U 12.2 General Voltage range - 10...230 V - 10...230 V - - - Voltage type - AC/DC - AC/DC - - - Contact scanning ■ - ■ - ■ ■ Inputs 4 4 8 8 2 4 12 Type of installation MDRC MDRC MDRC MDRC FM FM FM Module width (space unit) 2 2 4 4 - - - Switch sensor Send switch value after any edge ■ ■ ■ ■ ■ ■ ■ Send switch value after signal length and/or cyclically ■ ■ ■ ■ ■ ■ ■ Send switch value 1 cyclically ■ ■ ■ ■ ■ ■ ■ Send switch value 2 ■ ■ ■ ■ Send switch value 3 ■ ■ ■ ■ Difference between short and long operation ■ ■ ■ ■ ■ ■ ■ Dim sensor Start-stop dimming, step-by-step dimming ■ ■ ■ ■ ■ ■ ■ One-touch dimming ■ ■ ■ ■ ■ ■ ■ Shutter Sensor Shutter operation via a push button/switch ■ ■ ■ ■ ■ ■ ■ Shutter operation via two push buttons/switches ■ ■ ■ ■ ■ ■ ■ Value/Forced operation 1 bit [0/1], 2 bit forced operation ■ ■ ■ ■ ■ ■ ■ 1/2/4 bytes ■ ■ ■ ■ ■ ■ ■ Signed ■ ■ ■ ■ 3 byte, time, weekday ■ ■ ■ ■ Control scene 8 bit scene ■ ■ ■ ■ ■ ■ ■ Store scene ■ ■ ■ ■ ■ ■ ■ Switching sequence Several preset sequences can be set ■ ■ ■ ■ ■ ■ ■ Link several push buttons in a switching sequence (actuating number) ■ ■ ■ ■ ■ ■ ■ Multiple operation Telegram for long operation ■ ■ ■ ■ ■ ■ ■ Multiple operation can be set ■ ■ ■ ■ ■ ■ ■ Pulse counter Adjustable data type and threshold values ■ ■ ■ ■ ■ ■ Temporary counter activation ■ ■ ■ ■ ■ ■ Send counter level cyclically ■ ■ ■ ■ ■ ■ Manual operation Energy-saving mode Enable/release manual operation Manual operating status Enable/release manual operation button per input Input LED can be inverted Special functions Copying and exchanging parameter settings ■ ■ ■ ■ Enable/disable input ■ ■ ■ ■ ■ ■ ■ Adjustable debounce time and minimum signal time ■ ■ ■ ■ ■ ■ ■ Limit the number of telegrams ■ ■ ■ ■ ■ ■ ■ Device sends an "In operation" telegram" ■ ■ ■ ■ Heating valve control (electric relay) ■ ■ ■ Switch LEDs ■ ■ ■ ■ - Function is supported 10
-
P. 1
-
P. 7
More Security Through Flexibility During Planning, Commissioning and Operation The fundamental principle: One device per room A single Room Controller... -
P. 8
ABB i-bus® KNX Room Automation Overview of switching performance SA/M 2.6.1 SA/M 2.16.1 SD/M 2.6.2 LR/M 1.6.2 UD/M 1.300.1 ES/M 2.230.1 ES/M 2.24.1... -
P. 9
ABB i-bus® KNX Room Automation Type Dtail Order code PG MW Type Detail Order code PG MW Room Controller The Room Controller controls all the functions... -
P. 10
ABB i-bus® KNX Room Automation Room Master The Room Master is a KNX device with a combination of inputs and outputs. The quantities, technical data... -
P. 11
ABB i-bus® KNX Binary Inputs Application Opration of KNX Systems via conventional push buttons and switches Processing of binary signals (signalling... -
P. 12
-
P. 13
ABB i-bus® KNX Inputs Type Dtail Order code PG MW Type Detail Order code PG MW Binary Inputs, 10 - 230 V AC/DC, MDRC Detects AC/DC signals in the... -
P. 14
ABB i-bus® KNX Switch Actuators A Complte Range Switch Actuators are responsible for reliable switching of different electrical loads in the KNX system.... -
P. 15
ABB i-bus® KNX Switch Actuators Switching Capacity Overview The following table provides and overview of the rated values, switching performance,... -
P. 16
ABB i-bus® KNX Switch Actuators An Overview of all Software Functions Overview The following table provides an overview of the functions possible... -
P. 17
ABB i-bus® KNX Outputs Type Dtail Order code PG MW Type Detail Order code PG MW Switch Actuators, 6 A, MDRC Using floating contacts it switches 4,... -
P. 18
-
P. 19
-
P. 20
-
P. 30
-
P. 40
-
P. 50
-
P. 60
-
P. 70